New Journal Website is available at: http://www.journalonweb.com/rcm

Published by: Kowsar

Echocardiographic Evaluation of Cardiac Function in Ischemic Rats: Value of M-Mode Echocardiography

Amir Darbandi Azar 1 , Fatemeh Tavakoli 2 , Hassan Moladoust 3 , Asghar Zare 1 and Anita Sadeghpour 4 , *
Authors Information
1 Rajaie Cardiovascular, Medical and Research Centre, Iran University of Medical Sciences, Tehran, IR Iran
2 Department of Toxicology and Pharmacology, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran, IR Iran
3 Department of Medical Physics and Biomedical Engineering, Guilan University of Medical Sciences, Rasht, IR Iran
4 Echocardiography Research Center, Department of Cardiovascular Medicine, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, IR Iran
Article information
  • Research in Cardiovascular Medicine: November 2014, 3 (4); e22941
  • Published Online: November 1, 2014
  • Article Type: Research Article
  • Received: August 20, 2014
  • Accepted: October 8, 2014
  • DOI: 10.5812/cardiovascmed.22941

To Cite: Darbandi Azar A, Tavakoli F, Moladoust H, Zare A, Sadeghpour A. et al. Echocardiographic Evaluation of Cardiac Function in Ischemic Rats: Value of M-Mode Echocardiography, Res Cardiovasc Med. 2014 ;3(4):e22941. doi: 10.5812/cardiovascmed.22941.

Abstract
Copyright: Copyright © 2014, Research in Cardiovascular Medicine. .
1. Background
2. Objectives
3. Materials and Methods
4. Results
5. Discussion
Acknowledgements
Footnotes
References
  • 1. Holinski S, Knebel F, Heinze G, Konertz W, Baumann G, Borges AC. Noninvasive monitoring of cardiac function in a chronic ischemic heart failure model in the rat: assessment with tissue Doppler and non-Doppler 2D strain echocardiography. Cardiovasc Ultrasound. 2011; 9: 15[DOI][PubMed]
  • 2. Watson LE, Sheth M, Denyer RF, Dostal DE. Baseline echocardiographic values for adult male rats. J Am Soc Echocardiogr. 2004; 17(2): 161-7[DOI][PubMed]
  • 3. Miranda A, Costa-e-Sousa RH, Werneck-de-Castro JP, Mattos EC, Olivares EL, Ribeiro VP, et al. Time course of echocardiographic and electrocardiographic parameters in myocardial infarct in rats. An Acad Bras Cienc. 2007; 79(4): 639-48[PubMed]
  • 4. Srikanth G, Prakash P, Tripathy N, Dikshit M, Nityanand S. Establishment of a rat model of myocardial infarction with a high survival rate: A suitable model for evaluation of efficacy of stem cell therapy. J Stem Cells Regen Med. 2009; 5(1): 30-6[PubMed]
  • 5. Brown L, Fenning A, Chan V, Loch D, Wilson K, Anderson B, et al. Echocardiographic assessment of cardiac structure and function in rats. Heart Lung Circ. 2002; 11(3): 167-73[DOI][PubMed]
  • 6. Oh JK, Seward JB, Tajik AJ. The Echo Manual. 2012;
  • 7. Feigenbaum H, Armstrong WF, Ryan T. Feigenbaum's Echocardiography. 2004;
  • 8. Guide for the Care and Use of Laboratory Animals. 2011; [PubMed]
  • 9. Fukuda S, Kaga S, Sasaki H, Zhan L, Zhu L, Otani H, et al. Angiogenic signal triggered by ischemic stress induces myocardial repair in rat during chronic infarction. J Mol Cell Cardiol. 2004; 36(4): 547-59[DOI][PubMed]
  • 10. Samsamshariat SA, Samsamshariat ZA, Movahed MR. A novel method for safe and accurate left anterior descending coronary artery ligation for research in rats. Cardiovasc Revasc Med. 2005; 6(3): 121-3[DOI][PubMed]
  • 11. Virag JA, Lust RM. Coronary artery ligation and intramyocardial injection in a murine model of infarction. J Vis Exp. 2011; (52)[DOI][PubMed]
  • 12. Schiller NB, Shah PM, Crawford M, DeMaria A, Devereux R, Feigenbaum H, et al. Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms. J Am Soc Echocardiogr. 1989; 2(5): 358-67[PubMed]
  • 13. Scheer P, Sverakova V, Doubek J, Janeckova K, Uhrikova I, Svoboda P. Basic values of M-mode echocardiographic parameters of the left ventricle in outbreed Wistar rats. Vet Med. 2012; 57(1): 42-52
  • 14. Wasmeier GH, Melnychenko I, Voigt JU, Zimmermann WH, Eschenhagen T, Schineis N, et al. Reproducibility of transthoracic echocardiography in small animals using clinical equipment. Coron Artery Dis. 2007; 18(4): 283-91[DOI][PubMed]
  • 15. Geyer H, Caracciolo G, Abe H, Wilansky S, Carerj S, Gentile F, et al. Assessment of myocardial mechanics using speckle tracking echocardiography: fundamentals and clinical applications. J Am Soc Echocardiogr. 2010; 23(4): 351-69[DOI][PubMed]
  • 16. Perk G, Tunick PA, Kronzon I. Non-Doppler two-dimensional strain imaging by echocardiography--from technical considerations to clinical applications. J Am Soc Echocardiogr. 2007; 20(3): 234-43[DOI][PubMed]
  • 17. Slama M, Susic D, Varagic J, Ahn J, Frohlich ED. Echocardiographic measurement of cardiac output in rats. Am J Physiol Heart Circ Physiol. 2003; 284(2)-7[DOI][PubMed]
Creative Commons License Except where otherwise noted, this work is licensed under Creative Commons Attribution Non Commercial 4.0 International License .

Search Relations:

Author(s):

Article(s):

Create Citiation Alert
via Google Reader